Jual Inverter VSD LS iP5A



Spesifikasi Inverter VSD LS iP5A

Deskripsi

Common
specfications Dynamic braking torque Max. braking torque 20% continuous4)
ED Option ( braking UNIT, braking resistor) 4)
Cooling method Forced air cooling
Protection degree IP20, UL Enclosed Type 1( provided with conduit box) for all ratings, UL Open type from 15 to 90 kW ( Optional conduit plate)
Control Control method V/ F, Sensorless Vector, Slip Compensation, Easy Start Selectable
Frequency setting resolution Digital reference: 0.01Hz( Below 100Hz) , 0.1Hz( Over 100Hz) , Analog reference: 0.01Hz/ 60Hz
Frequency accuracy Digital: 0.01% of max. output freq
Analog: 0.1% of max. output freq
V/ F ratio Linear, Square pattern, User V/ F
Overload capacity 110% per 1min, 120% per 1min5)
Torque boost Manual torque boost( 0 to 15% adjustable) , auto torque boost
Operation Operation method Keypad/ Terminal/ Communication selectable
Frequency setting resolution Analog: 0~ 12V/ -12V~ 12V/ 4~ 20mA/ 0~ 20mA/ Pulse/ Ext-PID, Digital: Keypad
Input signal Start signal Forward, Reverse
Multi-Step Up to 18 Speeds can be set including Jog ( Use Programmable Digital InputTerminal)
Multi-Step Accel/ Decel time 0.1~ 6, 000 sec, Max 4 types can be set via Multi- Function Terminal.
Accel/ Decel Pattern: Linear, U-Curve, S-Curve Selectable
Emergency stop Interrupts the Output of Inverter
Jog Jog operation
Fault reset Reset the fault when the protective function is active.
Output signal Operating status Frequency Detection Level, Overload Alarm, Stalling, Over Voltage, Low Voltage, Inverter Overheating/ Running/ Stopping/ Constant running, Inverter By-Pass, Speed Searching
Fault output Contact Output ( 3A, 3C, 3B) - AC 250V 1A, DC 30V 1A
Indicatot Choose 2 from Output Frequency, Output Current, Output Voltage, DC Link
Voltage ( Output Voltage: 0 ~ 10V)
Operation function DC Braking, Frequency Limit, Frequency Jump, 2nd Function, Slip Compensation, Reverse Rotation Prevention, Auto Restart, Inverter By-Pass, Auto-Tuning, PID Control, Flying Start, Safety Stop, Flux Braking, Low leakage, Pre-PID, Dual-PID, MMC, Easy Start, Pre-heater
Protection function Inverter trip Over Voltage, Low Voltage, Over Current, Ground Fault , Inverter Overheat, Motor Overheat, Output Phase Open, Overload Protection, External Fault 1, 2, Communication Error, Loss of Speed Command, Hardware Fault, Option Fault, etc
Inverter alarm Stall Prevention, Overload Alarm, Thermal Sensor Fault
Momentary power loss Below 1 sec: Continuous operation, Above 1 sec: Auto restart active when Safety Stop is set to " Yes " with a fan connected.
Keypad Operation information Output Frequency, Output Current, Output Voltage, Frequency Set Value, Operating Speed, DC Voltage, Integrating Wattmeter, Fan ON time, Run-time, Last Trip Time.
Trip information Trips Indication when the Protection Function activates. Max. 5 Faults are saved. Last Trip Time.
Environment Ambient temperature -10 ~ 40 ( use loads less than 80% at 50 )
Storage temperature -20 ~ 65
Ambient humidity Less than 90% RH Max. ( No condensing)
Altitude, Vibration Below 1, 000m· Below 5.9m/ sec² ( = 0.6g)
Application site Pollution degree 2, No Corrosive Gas, Combustible Gas, Oil Mist, or Dust